{"product_id":"shunt-2000a50m-v","title":"Victron Shunt 2000A\/50mV","description":"\u003cp data-start=\"104\" data-end=\"185\"\u003eExtremely powerful precision shunt for measuring high current in large battery systems.\u003c\/p\u003e\n\u003cp data-start=\"187\" data-end=\"443\"\u003eThe Victron Shunt 2000A\/50mV is a high-precision measuring resistor used with battery monitors such as the BMV series or other compatible systems. It allows for accurate measurement of current consumption and charging – even in very large installations.\u003c\/p\u003e\n\u003cp data-start=\"445\" data-end=\"532\"\u003eThe shunt is mounted on the battery's negative terminal and acts as the central measurement point in the system.\u003c\/p\u003e\n\u003chr data-start=\"534\" data-end=\"537\"\u003e\n\u003cp data-start=\"539\" data-end=\"552\"\u003e⚡ \u003cstrong data-start=\"541\" data-end=\"552\"\u003eAdvantages\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"554\" data-end=\"827\"\u003e\n\u003cli data-section-id=\"1mv0yzo\" data-start=\"554\" data-end=\"600\"\u003e\n\u003cp data-start=\"556\" data-end=\"600\"\u003e2000A shunt for very large installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uvbz4l\" data-start=\"601\" data-end=\"644\"\u003e\n\u003cp data-start=\"603\" data-end=\"644\"\u003eAccurate measurement of current and energy consumption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"101udal\" data-start=\"645\" data-end=\"691\"\u003e\n\u003cp data-start=\"647\" data-end=\"691\"\u003eStandard 50mV signal (wide compatibility)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14psap3\" data-start=\"692\" data-end=\"736\"\u003e\n\u003cp data-start=\"694\" data-end=\"736\"\u003eRobust construction for demanding environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1grhs1k\" data-start=\"737\" data-end=\"774\"\u003e\n\u003cp data-start=\"739\" data-end=\"774\"\u003eLow resistance – minimal energy loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1p96teu\" data-start=\"775\" data-end=\"827\"\u003e\n\u003cp data-start=\"777\" data-end=\"827\"\u003eSuitable for professional and high-power systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"829\" data-end=\"890\"\u003eA shunt is the very foundation for accurate battery monitoring.\u003c\/p\u003e\n\u003chr data-start=\"892\" data-end=\"895\"\u003e\n\u003cp data-start=\"897\" data-end=\"915\"\u003e⛵ \u003cstrong data-start=\"899\" data-end=\"915\"\u003eSuitable for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"917\" data-end=\"1080\"\u003e\n\u003cli data-section-id=\"8wnjbi\" data-start=\"917\" data-end=\"956\"\u003e\n\u003cp data-start=\"919\" data-end=\"956\"\u003eLarge boats and marine installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1jq1fwb\" data-start=\"957\" data-end=\"992\"\u003e\n\u003cp data-start=\"959\" data-end=\"992\"\u003eHigh-power inverter setups (5kW+)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1irpced\" data-start=\"993\" data-end=\"1030\"\u003e\n\u003cp data-start=\"995\" data-end=\"1030\"\u003eOff-grid systems with high load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16sscj0\" data-start=\"1031\" data-end=\"1080\"\u003e\n\u003cp data-start=\"1033\" data-end=\"1080\"\u003eIndustrial and professional energy systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1082\" data-end=\"1085\"\u003e\n\u003cp data-start=\"1087\" data-end=\"1109\"\u003e📊 \u003cstrong data-start=\"1090\" data-end=\"1109\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1111\" data-end=\"1578\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1111\" data-end=\"1135\"\u003e\n\u003ctr data-start=\"1111\" data-end=\"1135\"\u003e\n\u003cth data-start=\"1111\" data-end=\"1127\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1127\" data-end=\"1135\" data-col-size=\"sm\" class=\"\"\u003eData\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1159\" data-end=\"1578\"\u003e\n\u003ctr data-start=\"1159\" data-end=\"1189\"\u003e\n\u003ctd data-start=\"1159\" data-end=\"1169\" data-col-size=\"sm\"\u003eProduct\u003c\/td\u003e\n\u003ctd data-start=\"1169\" data-end=\"1189\" data-col-size=\"sm\"\u003eShunt 2000A\/50mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1190\" data-end=\"1214\"\u003e\n\u003ctd data-start=\"1190\" data-end=\"1204\" data-col-size=\"sm\"\u003eMax. current\u003c\/td\u003e\n\u003ctd data-start=\"1204\" data-end=\"1214\" data-col-size=\"sm\"\u003e2000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1215\" data-end=\"1233\"\u003e\n\u003ctd data-start=\"1215\" data-end=\"1224\" data-col-size=\"sm\"\u003eSignal\u003c\/td\u003e\n\u003ctd data-start=\"1224\" data-end=\"1233\" data-col-size=\"sm\"\u003e50 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1234\" data-end=\"1300\"\u003e\n\u003ctd data-start=\"1234\" data-end=\"1248\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-start=\"1248\" data-end=\"1300\" data-col-size=\"sm\"\u003eapprox. ±0.5 % \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1301\" data-end=\"1361\"\u003e\n\u003ctd data-start=\"1301\" data-end=\"1312\" data-col-size=\"sm\"\u003eTerminal\u003c\/td\u003e\n\u003ctd data-start=\"1312\" data-end=\"1361\" data-col-size=\"sm\"\u003e3 × M10 \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1362\" data-end=\"1389\"\u003e\n\u003ctd data-start=\"1362\" data-end=\"1373\" data-col-size=\"sm\"\u003eResistance\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1373\" data-end=\"1389\"\u003eapprox. 0.025 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1390\" data-end=\"1466\"\u003e\n\u003ctd data-start=\"1390\" data-end=\"1404\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"1404\" data-end=\"1466\" data-col-size=\"sm\"\u003eapprox. 168 × 80 × 50 mm \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1467\" data-end=\"1532\"\u003e\n\u003ctd data-start=\"1467\" data-end=\"1474\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"1474\" data-end=\"1532\" data-col-size=\"sm\"\u003eapprox. 2.2 – 2.3 kg \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1533\" data-end=\"1578\"\u003e\n\u003ctd data-start=\"1533\" data-end=\"1546\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"1546\" data-end=\"1578\" data-col-size=\"sm\"\u003eCurrent measurement \/ battery monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1580\" data-end=\"1583\"\u003e\n\u003cp data-start=\"1585\" data-end=\"1604\"\u003e🔧 \u003cstrong data-start=\"1588\" data-end=\"1604\"\u003eInstallation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"1606\" data-end=\"1633\"\u003eThe shunt is typically installed:\u003c\/p\u003e\n\u003cul data-start=\"1635\" data-end=\"1815\"\u003e\n\u003cli data-section-id=\"6le9e6\" data-start=\"1635\" data-end=\"1658\"\u003e\n\u003cp data-start=\"1637\" data-end=\"1658\"\u003eOn the battery's negative terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18n28py\" data-start=\"1659\" data-end=\"1703\"\u003e\n\u003cp data-start=\"1661\" data-end=\"1703\"\u003eBetween the battery and all loads\/chargers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1zg3es\" data-start=\"1704\" data-end=\"1751\"\u003e\n\u003cp data-start=\"1706\" data-end=\"1751\"\u003eTogether with a battery monitor (BMV or similar)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wjx96f\" data-start=\"1752\" data-end=\"1815\"\u003e\n\u003cp data-start=\"1754\" data-end=\"1815\"\u003eWith correctly sized cables (very important at 2000A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1817\" data-end=\"1885\"\u003e⚠️ All negative connections must pass through the shunt for correct measurement.\u003c\/p\u003e\n\u003chr data-start=\"1887\" data-end=\"1890\"\u003e\n\u003cp data-start=\"1892\" data-end=\"1915\"\u003e📦 \u003cstrong data-start=\"1895\" data-end=\"1915\"\u003ePackage contents\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1917\" data-end=\"1949\"\u003e\n\u003cli data-section-id=\"1qthxub\" data-start=\"1917\" data-end=\"1949\"\u003e\n\u003cp data-start=\"1919\" data-end=\"1949\"\u003e1 × Victron Shunt 2000A\/50mV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1951\" data-end=\"1954\"\u003e\n\u003cp data-start=\"1956\" data-end=\"2154\"\u003e💡 \u003cstrong data-start=\"1959\" data-end=\"1981\"\u003eTip from SejlStrøm:\u003c\/strong\u003e\u003cbr data-start=\"1981\" data-end=\"1984\"\u003e2000A is only for the very largest setups. If you're not operating at that scale, it's better (and cheaper) to choose 500A or 1000A – but with this, you're covered for EVERYTHING 👍\u003c\/p\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":56879610331511,"sku":"SHU202050200","price":1168.75,"currency_code":"DKK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/1369\/2791\/files\/victron-shunt-2000a50mv-6143962.jpg?v=1773867024","url":"https:\/\/sejlstroem.dk\/en\/products\/shunt-2000a50m-v","provider":"SejlStrøm","version":"1.0","type":"link"}